T3-1-2-K Sandwich-type Ultrasonic Water Meter (DN50-150)
The highly integrated T3-1-2-K sandwich-type ultrasonic water meter is designed and manufactured strictly according to GB/T778.1-2007,ISO4064-1:2005 etc. based on ultrasound transit-time measurement technology.
Todos los contadores estarán garantizados contra defectos de fabricación y materiales durante un periodo de un (1) año a partir de la fecha de aceptación. Los contadores o piezas defectuosos descubiertos dentro de este periodo serán sustituidos sin cargo alguno tras su devolución a HBM Meters.
Parts Description
T3-1-2-K ultrasonic water meter has wired type as standard configuration, wireless type need to be customized.
Menu Instruction
Operation Method
Water meter is equipped with two touch keys “ ▲ ” and “ ▶︎ “, slide from “ ▲ ” to “▶︎ ” is “ ▲▶︎” key to edit, slide from “▶︎” to “▲” is the key to quit.
Formula: up click ”▲”is up: down click ”▶︎ ”is down;
Slide from up to down ”▲▶︎” is modification : Slide from down to up ”▶︎▲” is quit.
Windows Display lnstructior
Windows: No.Windows Functions
Main Menu:
M01:Display net cumulative and instantaneous flow
M02:Display supply and return water temperature and temperature difference.
M03:Calendar, display date and week on first line, display hour and minute on second line.
M04:Display signal strength and error code on first line, display voltage and temperature on second line.
M05:Calibration Menu
M06:Batch Controller(lrrigation controller)
M07:Display ESN and software version
Water meter includes 5 kinds of menus: main menu, secondary menu 1, secondary menu 2. batch control menu and time-accumulated menu. You can enter any menus by the modification key “▲▶︎”
Example:
On M01. press “▲▶︎” to access month cumulative flow
On M03. press“▲▶︎”to access secondarv menu 1(M10~M19)
On M19 of secondary menu 1 press “▲▶︎ ” to access secondary menu 2 (M20-M2A).
On M04. press“▲▶︎”to access day cumulative flow.
On M05(start-stop calibration state). press “▲▶︎” to access constant-current method calibration state
On M06, press “▲▶︎” to access batch control and time-accumulative menu (M30~M3C).
Calibration Method
Our water meter is calibrated via constant-current method.
Installation Instructions