DN15-6000mm Fixed Separated Ultrasonic Flowmeter

DN15-6000mm Fixed Separated Ultrasonic Flowmeter

This flowmeter can be virtually applied to a wide range of measurement. A variety of liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage,reclaimed water, cooling water, river water, plant effluent. etc

All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the HBM Meters.

    Category:

    Features

    High Reliability

    Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.

    Wide measuring range

    Several types transducer for selection, pipe size from Dn15mm to Dn6000mm

    High Reliability

    Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.

    Strong Anti-interference

    Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.

    Powerful Recording Function

    Automatically record the following data :

    1. The totalizer data of the last 512 days/128 months/10 years
    2. The time and corresponding flow rate of the last 64 times of power on and off events
    3. The working status of the last 32 days

    Support Heat Measurement

    Connect the temperature transducer ,can finish the heat/energy measurement

    Support SD card Memory

    Optional SD card

    item
    value
    Warranty
    2 yaers
    Place of Origin
    Hebei
    Brand Name
    HBM
    Model Number
    Clamp on
    Type
    Variable Area Water Flowmeters
    Product Name
    Fixed Separated Ultrasonic Flowmeter
    Display
    LCD Display
    Size
    DN15mm~DN6000mm
    Color
    Picture Show
    Temperature
    -30~160℃
    Measuring range
    DN80~DN6000
    Material
    Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC
    Keywords
    Liquid Control Flow Meter
                  Items                                                                         Performance & Parameter
    Convertor
    Principle
    Transit-time ultrasonic flowmeter
    Accuracy
    ±1%
    Display
    2×20 character LCD with backlight, support the language of Chinese, English and Italy
    Signal Output
    1 way 4~20mA output, electric resistance 0~1K,accuracy0.1%
    1 way OCT pulse output(Pulse width 6~1000ms,default is 200ms)
    1 way Relay output
    Signal Input
    3 way 4~20mA input, accuracy 0.1%,acquisition signal such as temperature, press and liquid level
    Connect the temperature transducer Pt100, can finish the heat/energy measurement
    Data Interface
    Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS
    Special Cable
    Twisted-pair cable, generally, the length under 50 meters; Select the RS485, transmission distance can over 1000m
    Pipe Installation Condition
    Pipe Material
    Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed
    Pipe Diameter
    15~6000mm
    Straight Pipe
    Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump
    Measuring Medium
    Type of Liquid
    Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage
    with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, etc.); Plant
    effluent; Beverage; Ultra-pure liquids, etc.
    Temperature
    -30~160℃
    Turbidity
    No more than 10000ppm and less bubble
    Flowrate
    0~±7m/s
    Working Environment
    Temperature
    Convertor:-20~60℃;Flow Transducer:-30~160℃
    Humidity
    Convertor: 85%RH;Flow Transducer:can measure under water,water depth≤2m(tansducer sealed glue)
    Power Supply
    DC8~36V or AC85~264V(optional)
    Power Consumption
    1.5W
    Dimension
    205*154*70cm(convertor)

    Measuring Diagram

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Optional Convertor

     

     

     

     

     

     

    Optional Transducers

     

     

     

     

     

     

     

     

     

     

     

    Optional Temperature Transducers

     

     

     

     

     

    Optional SD card memory

    The SD card memory can be expanded to 2GB, which can achieve the ultrasonic flowmeter measurement data mass storage, can solve the problems for wall-mounted flowmeter measurement data stored, reading, and processing inconvenience, can completely replace manual meter reading, no paper records instrument.In addition, the SD memory card measurements data, can be used by our company’s “Flow data analysis, statistical software” for processing, including the tabulation, statistical, data analysis,printing reports, production flow curve and other functions.

     

     

     

    Open chat