DN15-6000mm Fixed Separated Ultrasonic Flowmeter
This flowmeter can be virtually applied to a wide range of measurement. A variety of liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage,reclaimed water, cooling water, river water, plant effluent. etc
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the HBM Meters.
Features
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Wide measuring range
Several types transducer for selection, pipe size from Dn15mm to Dn6000mm
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function
Automatically record the following data :
- The totalizer data of the last 512 days/128 months/10 years
- The time and corresponding flow rate of the last 64 times of power on and off events
- The working status of the last 32 days
Support Heat Measurement
Connect the temperature transducer ,can finish the heat/energy measurement
Support SD card Memory
Optional SD card
item
|
value
|
Warranty
|
2 yaers
|
Place of Origin
|
Hebei
|
Brand Name
|
HBM
|
Model Number
|
Clamp on
|
Type
|
Variable Area Water Flowmeters
|
Product Name
|
Fixed Separated Ultrasonic Flowmeter
|
Display
|
LCD Display
|
Size
|
DN15mm~DN6000mm
|
Color
|
Picture Show
|
Temperature
|
-30~160℃
|
Measuring range
|
DN80~DN6000
|
Material
|
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC
|
Keywords
|
Liquid Control Flow Meter
|
Items Performance & Parameter
|
||||
Convertor
|
Principle
|
Transit-time ultrasonic flowmeter
|
||
Accuracy
|
±1%
|
|||
Display
|
2×20 character LCD with backlight, support the language of Chinese, English and Italy
|
|||
Signal Output
|
1 way 4~20mA output, electric resistance 0~1K,accuracy0.1%
|
|||
1 way OCT pulse output(Pulse width 6~1000ms,default is 200ms)
|
||||
1 way Relay output
|
||||
Signal Input
|
3 way 4~20mA input, accuracy 0.1%,acquisition signal such as temperature, press and liquid level
|
|||
Connect the temperature transducer Pt100, can finish the heat/energy measurement
|
||||
Data Interface
|
Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS
|
|||
Special Cable
|
Twisted-pair cable, generally, the length under 50 meters; Select the RS485, transmission distance can over 1000m
|
|||
Pipe Installation Condition
|
Pipe Material
|
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed
|
||
Pipe Diameter
|
15~6000mm
|
|||
Straight Pipe
|
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump
|
|||
Measuring Medium
|
Type of Liquid
|
Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage
with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, etc.); Plant effluent; Beverage; Ultra-pure liquids, etc. |
||
Temperature
|
-30~160℃
|
|||
Turbidity
|
No more than 10000ppm and less bubble
|
|||
Flowrate
|
0~±7m/s
|
|||
Working Environment
|
Temperature
|
Convertor:-20~60℃;Flow Transducer:-30~160℃
|
||
Humidity
|
Convertor: 85%RH;Flow Transducer:can measure under water,water depth≤2m(tansducer sealed glue)
|
|||
Power Supply
|
DC8~36V or AC85~264V(optional)
|
|||
Power Consumption
|
1.5W
|
|||
Dimension
|
205*154*70cm(convertor)
|
Measuring Diagram
Optional Convertor
Optional Transducers
Optional Temperature Transducers
Optional SD card memory
The SD card memory can be expanded to 2GB, which can achieve the ultrasonic flowmeter measurement data mass storage, can solve the problems for wall-mounted flowmeter measurement data stored, reading, and processing inconvenience, can completely replace manual meter reading, no paper records instrument.In addition, the SD memory card measurements data, can be used by our company’s “Flow data analysis, statistical software” for processing, including the tabulation, statistical, data analysis,printing reports, production flow curve and other functions.